Simultaneous Thermal Analyzer for Laboratory Material Testing

Number:

DH-STA300

Activity price:

¥

Market price:

¥


Details


Related Products

Simultaneous Thermal Analyzer for Laboratory Material Testing

 

 

Application:

The synchronous thermal analyzer can detect TGA/DSC information at the same time, and has a wide range of measurement, including: thermal stability, redox, decomposition behavior, corrosion research, decomposition kinetics analysis, melting/crystallization, solid phase transition, crystallinity, glass transition, etc.

The synchronous thermal analyzer is widely used in research and development, process optimization and quality monitoring in various fields such as plastics, rubber, coatings, pharmaceuticals, catalysts, inorganic materials, metal materials and composite material.

 

 

Principles:

The working principle of the synchronous thermal analyzer is based on the temperature change of the sample and the conduction, absorption and radiation of heat. It controls the temperature of the heating furnace to heat, cool and maintain the temperature of the sample, and then detects and records the temperature change and corresponding physical and chemical properties of the sample.

 

 

Structural Advantages:

1. The furnace body heating adopts double-row winding of precious metal alloy wire to reduce interference and is more resistant to high temperature.

2. The tray sensor is made of precious metal alloy trays, which has the advantages of high temperature resistance, oxidation resistance and corrosion resistance.

3. The power supply, circulating heat dissipation part and the main unit are separated to reduce the influence of heat and vibration on the microthermal balance.

4. The upper cover structure is adopted, which is easy to operate and has an exhaust gas output port, which is convenient for expanding the connection of infrared and other equipment.

5. The main unit uses an isolated heating furnace to isolate the thermal influence of the chassis and the microthermal balance.

6. The furnace body adopts double insulation, which has better linearity.

7. The imported weighing system uses a ceramic rod to connect with the sample tray, which can be plugged in and out; the sample rod can be replaced according to different experiments to meet different test requirements.

 

Controller and Software Advantages:

1. Using imported ARM processors, the sampling speed and processing speed are faster.

2. Four-way sampling AD collects TG signals and temperature T signals.

3. Heating control, different from the relay heating method on the market, adopts PID algorithm for precise temperature control. At the same time, it can measure the cooling scan.

4. USB bidirectional communication is used between the software and the instrument to fully realize remote operation. The instrument parameters can be set and the operation of the instrument can be stopped through the computer software.

5. 7-inch full-color 24-bit touch screen, better human-machine interface. TG calibration can be achieved on the touch screen.

 

Technical Parameters:

1) Temperature range: room temperature ~ 1450℃

2) Temperature resolution: 0.01℃

3) Temperature fluctuation: ±0.1℃

4) Heating rate: 0.1~100℃/min

5) Temperature control method: PID algorithm control, heating, constant temperature, cooling

6) Cooling method: water cooling

7) Balance measurement range: 0.01mg~3g, can be expanded to 30g

8) Program control, realize multi-stage heating control; the program can set at least 5 sections; the constant temperature time can be set arbitrarily

9) Weighing system accuracy: 0.01mg

10) Resolution: 0.1ug

11) DSC Range: ±800mw

12) DSC accuracy: 0.01mw

13) DSC resolution: 0.01uw

14) Display mode: 24bit color, 7-inch LCD touch screen display

15) Atmosphere device: built-in gas flow meter, including two-way gas switching and flow control

Atmosphere: inert, oxidizing, reducing, static, dynamic; gas introduction time can be set by program, and the atmosphere can be switched by program during the test

16) Software: Intelligent software can automatically record TG curves for data processing and print experimental reports

17) Curve scanning: temperature scanning, temperature scanning

18) Power supply: AC220V 50Hz; heating power ≤1000w

19) Operating software: data acquisition frequency can be customized, set the acquisition frequency in real time, 2S, 5S, 10S, custom;

20) Communication interface: USB communication, two-way communication

21) The instrument lower computer has temperature multi-point correction, at least meeting 3 Point calibration, high, medium and low temperature, no need to operate on the computer

22) The instrument has a water cooling port and a water cooling device (water cooling device temperature range: -10~100℃, adjustable)

23) The instrument has the initial atmosphere, purge and emptying functions, program control, and emptying time setting before the experiment.